  Datasheet File OCR Text:
  withstand voltage isolation resistance i/p-o/p:3.75kvac i/p-fg:1.88kvac o/p-fg:0.5kvac i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh constant current region note.4 specification model dc voltage rated current rated power output voltage adj. range current adj. range line regulation load regulation setup, rise time note.6 hold up time (typ.) voltage range note.5 frequency range power factor (typ.) efficiency (typ.) ac current (typ.) input inrush current( .) typ leakage current safety standards working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing over current note.4 over voltage over temperature can be adjusted by internal potentiometer or through output connecto r 1500ms, 80ms / 115vac 0ms, 80ms / 230vac at full load at full load 100 16ms/230vac 16ms/115vac at full load 90 ~ 305vac 127 ~ 431vdc 47 ~ 63hz pf>0.98/115vac, pf>0.95/230vac, pf>0.92/277vac at full load (pl ease refer to "power factor characteristic" curve) 0.43a / 115vac 0.24a / 230vac 0.23a / 277vac cold start 70a/230vac <0.75ma / 277vac 95 ~ 108% protection type : constant current limiting, recovers automatical ly after fault condition is removed -40 ~ +70 (refer to "derating curve") 20 ~ 95% rh non-condensing -40 ~ +80 , 10 ~ 95% rh 0.03%/ (0 ~ 50 ) 10 ~ 500hz, 2g 12min./1cycle, period for 72min. each along x, y, z axes 287.9khrs min. mil-hdbk-217f (25 ) 147*53*27mm (l*w*h) 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. constant current operation region is within 60% ~100% rated output vol tage. this is the suitable operation region for led related application s, but please reconfirm special electrical requirements for some specific syste m design. 5. derating may be needed under low input voltages. please check the static c haracteristics for more details. 6. length of set up time is measured at cold first start. turning on/off the powe r supply may lead to increase of the set up time. 7. the power supply is considered as a component that will be operated in combi nation with final equipment. since emc performance will be affected by t he complete installation, the final equipment manufacturers must re- qualify emc directive on the complete installation again. 0.2kg;72pcs/15.4kg/1.09cuft protection type : shut down o/p voltage, re-power on to recover 40w single output switching power supply universal ac input / full range (up to 305vac)built-in active pfc function protections: short circuit / over current / over voltage / over temperature cooling by free air convection output constant current level adjustable three in one dimming function (1~10vdc or pwm signal or resistance) suitable for built in led lighting system 3 years warranty suitable for dry / damp locations class 2 power unit100% full load burn-in test features : h l p - 4 0 h s e r i e s ripple & noise (max.) note.2 voltage tolerance note.3 environment safety & emc protection 85 10 (rth2) protection type : shut down o/p voltage, re-power on to recover 87% 87% 88% 88% 88.5% 89% 89.5% 89% 89.5% 2.5% 2 ~ 3.33a 2.0% 1.6 ~ 2.67a 1.0% 1.2 ~ 2a 1.0% 1 ~ 1.67a 1.0% 0.8 ~ 1.34a 1.0% 0.67 ~ 1.12a 1.0% 0.5 ~ 0.84a 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 2.0% 1.5% 1.0% 0.5% 0.5% 0.5% 0.5% 1.0% 0.45 ~ 0.75a 0.5% 0.5% 1.0% 0.58 ~ 0.96a 0.5% 0.5% 12v hlp-40h-12 HLP-40H-15 hlp-40h-20 hlp-40h-24 hlp-40h-30 h lp-40h-36 hlp-40h-42 hlp-40h-48 hlp-40h-54 7.2 ~12v 15v 9 ~ 15v 20v 12 ~ 20v 24v 14.4 ~ 24v 30v 18 ~ 30v 36v 21.6 ~ 36v 48v 28.8 ~ 48v 3.33a 2.67a 2a 1.67a 1.34a 1.12a 0.84a 40w 40w 40w 40.1w 40.2w 40.3w 40.3w 150mvp-p 150mvp-p 13.5 ~ 17v 150mvp-p 17 ~ 22v 150mvp-p 22 ~ 27v 200mvp-p 27 ~ 33v 200mvp-p 33 ~ 40v 300mvp-p 44 ~ 53v 10.8 ~ 13.5v 54v 32.4 ~ 54v 0.75a 40.5w 300mvp-p 49 ~ 58v 42v 25.2 ~ 42v 0.96a 40.3w 300mvp-p 40 ~ 46v 18 ~ 24v 15 ~ 21v 23 ~ 30v 28 ~ 35v 35 ~ 43v 41 ~ 49v 48 ~ 58v 59 ~ 68v 54 ~ 63v compliance to en55015, en61000-3-2 class c ( 60% load) ; en61000-3-3 compliance to en61000-4-2,3,4,5,6,8,11; en61547, en55024, lig ht industry level (surge 4kv), criteria a emc immunity emc emission selv m m ( except for 48v,54v ) ( for 48v,54v only) short circuit hiccup mode, recovers automatically after fault condition is remove d file name:hlp-40h-spec 2012-03-01 ul8750, csa c22.2 no. 250.0-08 (except for 48v, 54v), en61347-1, en613 47-2-13 approved ; design refer to ul60950-1, tuv en60950-1, en60335-1
mechanical specification unit:mm ac input connector (cn1) : jst b6p-vh or equivalent pin no. 13 6 2,4,5 assignment ac/l ac/n fg no pin mating housing jst vhr jst svh-21t-p1.1 or equivalent or equivalent terminal dc output connector (cn2) : jst b6p-vh or equivalent pin no. 12 3,4 5,6 assignment dim+ dim- mating housing jst vhr or equivalent terminal jst svh-21t-p1.1 or equivalent 3max. 27max. 53 43 t3.15a/300v fs1 cn2 53 42 1 6 cn1 53 42 1 6 3.5 140 147 5 -v +v io adj svr1 svr2 vo adj fosc : 100khz block diagram derating curve static characteristics input voltage (v) 60hz 90 100 125 135 145 155 165 175 180 200 230 305 100 90 80 70 60 50 40 load (%) 230vac input only ambient temperature ( ) load (%) -40 -25 0 -10 15 30 50 60 70 20 40 50 60 80 100 (horizontal) dim+ dim- detection pwm & pfc circuit o.l.p. o.t.p. emi filter rectifiers power switching filter & rectifiers +v -v i/p fg control o.v.p. & o.l.p. pfc circuit : grounding required 40w single output switching power supply h l p - 4 0 h s e r i e s file name:hlp-40h-spec 2012-03-01
70 72 74 76 78 80 82 84 86 88 90 92 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 277vac 230vac 115vac 0 .8 5 0 .8 6 0 .8 7 0 .8 8 0 .8 9 0 .9 0 .9 1 0 .9 2 0 .9 3 0 .9 4 0 .9 5 0 .9 6 0 .9 7 0 .9 8 0 .9 9 1 5 0 % 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 % 2 7 7 v a c 2 3 0 v a c 1 1 5 v a c there are two major kinds of led drive method "direct drive" and "with led driv er". typical led power supply i-v curve a typical led power supply may either work in "constant voltage mode (cv) or c onstant current mode (cc)" to drive the leds. mean well's led power supply with cv+ cc characteristic can b e operated at both cv mode (with led driver, at area (a) and cc m ode (direct drive, at area (b). driving methods of led module vo(%) 100 60 50 95 (max.) io (%) constant voltage area constant current area hiccup protection (a) (b) (c) hlg-40h series possess superior working efficiency that up to 89.5% can b e reached in field applications. efficiency vs load (48v model) power factor characteristic load efficiency (%) pf load constant current mode (40w) 40w single output switching power supply h l p - 4 0 h s e r i e s file name:hlp-40h-spec 2012-03-01
dimming operation 60k 60% 60% 10k 10k /n 20k /n 30k /n 40k /n 50k /n 60k /n 70k /n 80k /n 90k /n 100k /n single driver multiple drivers (n=driver quantity for synchronized dimming operation) 1v 4v 7v 2v 5v 8v 3v 6v 9v 10v 10% 10% 20k 20% 20% 30k 30% 30% 40k 40% 40% 50k 50% 50% 70k 70% 70% 80k 80% 80% 90k 100k open open open 90% 90% 100% 100% resistance value dimming value percentage of rated current percentage of rated current reference resistance value for output current adjustment (typical ) please do not connect "dim-" to "-v". 1 ~ 10v dimming function for output current adjustment (typical) 60% 60% 10% 10% 20% 20% 30% 30% 40% 40% 50% 50% 70% 70% 80% 80% 90% 90% 100% 100% duty value percentage of rated current 95%~105% ----- 95%~105% 95%~105% 10v pwm signal for output current adjustment (typical): frequency ra nge :100hz ~ 3khz ac/l ac/n fg dim+ dim- -v -v +v +v output constant current level can be adjusted through output connecto r by 1~10vdc, pwm signal, or connecting a resistance between dim+ and dim-. 40w single output switching power supply h l p - 4 0 h s e r i e s file name:hlp-40h-spec 2012-03-01 using a switch and relay can turn on/off the lighting fixture. 1.output constant current level can be adjusted through output connec tor by connecting a or 1~10vdc or 10v pwm signal between dim+ and dim-. resistance 2.the led lighting fixture can be turned on/off by the switch. n fg l relay blue brown green/ yellow ac/l ac/n hlp-40h dim+ dim- v(-) v(+) blue white black red switch adjuster 0~100k ohms resistance 1~10v dc voltage 10v pwm signal dimming connection diagram for turning the lighting fixture on/off : using the built-in dimming function can't turn the lighting fixture tot ally dark. please refer to the connection method below to achieve 0% bright ness of the lighting fixture connecting to the led power supply unit. led lighting fixture


▲Up To Search▲   

 
Price & Availability of HLP-40H-15

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X